Product Type: Fuses / Circuit Protection

ADR Series

A new standard for DIN rail-mounting hydraulic-magnetic circuit breakers. The Heinemann ADR series is the evident choice for manufacturers willing to integrate their design with hydraulic-magnetic technology without additional redesign effort. In addition to all the advantages of hydraulic-magnetic circuit breakers such as precise, stable, and reliable protection against overload or short-circuits, ADR provides the same Fit and Form as standard MCB: a great advantage for simplifying refurbishment or technology upgrade.

Features

  • Hydraulic-magnetic overcurrent and fast short-circuit protections
  • Different tripping curves
  • In-Rush capabilities (8x – 15x – 22xIn) in standard
  • Changeover (SPDT) auxiliary contact (C-NO-NC) embedded on the same pole as the circuit breaker
  • Different configurations and types of auxiliary contact connections
  • Midtrip options: handle falls to horizontal position on electrical tripping
  • Trip-free design: breaker cannot be defeated by holding the handle in the ON position
  • Power to the circuit breakers can be fed from the line or load side
  • Easy installation on DIN 35mm rail according to DIN 50022 (IEC/EN60715)
  • Module width of only 17.5 mm (per pole)
  • Captive screws cannot be lost
  • Captive terminals
  • Optional handle locking system for Logout/Tagout

C Series

The C Series is popular in outdoor locations, in either high-temperature or low-temperature environments where nuisance tripping might have been a problem in the past. The C Series is built for a wide range of applications and is one of the most versatile designs. From heating and air conditioning to modern railcars, the C Series breaker is built for the most demanding industrial applications.

Features

  • Environmental, Vibration, and Shock Resistant: Mil-spec qualification for fungus resistance, humidity, salt spray resistance, and shock vibration resistance.
  • Heat-Induced Nuisance Tripping Eliminated: The protector is designed to “hold in” at 100% continuous rated current, regardless of ambient temperatures from -40°C +85°C.
  • Immediate Reset After Trip: The protector can be reset (closed) immediately after an overcurrent trip without a “cooling off” period.
  • 1/2 Cycle High Inrush Tolerance – 8X (standard) and 25x: The protector is available with different levels of tolerance to 1/2 cycle current spikes. Standard tolerance is 8X the continuous current rating; in addition, 25X is also available.
  • Overcurrent Curves, Long, Medium, or Short Delay: Time characteristic curves are available as Short, Medium, and Long Delay.

GH Series

The GH Series breaker offers the benefits of hydraulic-magnetic protection in a compact, economical design. Because of their ability to furnish both close-rated locked rotor protection and running overcurrent protection without derating in extreme and highly variable ambient conditions, they are popular in a variety of industries — air conditioning, electric heating, computer main frame and central processing, transportation, and many others.

Features

  • Fungus and Humidity Resistance: Provided in accordance with MIL-STD-202 by treating all ferrous parts with a special moisture-resistant finish and using special springs and fungus-resistant cases, covers, and handles.
  • Shock: Tested in accordance with MIL-STD-202, Method 213, Test Condition I (100G’s at 6 milliseconds).
  • Vibration: Tested in accordance with MIL-STD-202, Method 204, 10 to 500 Hz, 0.06-inch total excursion on three mutually perpendicular planes. Shock and vibration tests apply to time delay breakers only and are performed with units carrying full rated current.

BAB Bolt-On Miniature Circuit Breakers

Eaton’s bolt-on miniature circuit breakers (Quicklag) provide superior protection in panel boards and offer easy installation. They are also switching duty rated for 120 VAC fluorescent light applications, and UL 489 listed. All products 15–100A are HACR rated.  Select from one-, two-, or three-pole designs.

Features

  • Flexible power feed connection (wire size and position) offers product uniformity and ease of installation.
  • Field-mountable accessories make installation and on-site custom configuration easy.
  • Compact designs available to minimize panel size.

DG12

Description

  • Panel mount: Screw-on or snap-in mounting from front side
  • 3 Functions: Appliance Inlet protection class I or II, Circuit breaker type TA35 2-pole, Line filter in standard and medical version
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • IP67 protection
  • Recessed rocker switch
  • Various mounting options
  • V-Lock cord retaining

Characteristics

  • All single elements are already wired
  • Circuit Breaker non-illuminated or illuminated
  • Suitable for use in equipment according to IEC/UL 60950
  • Suitable for use in medical equipment according to IEC/UL 60601-1

DD14

Description

  • Panel mount: Snap-in or screw-on mounting from front side
  • 4 Functions: Appliance Inlet Protection class I, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1  or 2 pole, 2-Stages line filter in standard and medical version
  • V-Lock notch standard
  • Quick connect terminals 6.3 x 0.8 mm

Unique Selling Proposition

  • Most compact power entry module with 2-stages filter
  • Attractive flat design
  • Various mounting options
  • V-Lock cord retaining

Characteristics

  • Ultra-compact design. Ideal for low profile designs
    Aluminum case provides good shielding
  • All single elements are already wired
  • Fuse drawer meets requirements of medical standard IEC/EN 60601-1
  • Ideal for application with high transient loads
  • Suitable for use in equipment according to IEC/UL 60950
    Suitable for use in medical equipment according to IEC/UL 60601-1

SHF Fuse

Description

  • 6.3 x 32 mm fuses for primary protection
  • 19 rated currents from 0.5 A to 32 A
  • Pigtails optional

Unique Selling Proposition

  • High rated voltages up to 500 VAC / VDC
  • High breaking capacity ≥ 1500 A

Applications

  • 3-phase applications
  • DC applications
  • Power supplies
  • Frequency converter
  • Power electronics

TA35

Description

  • Thermal circuit breaker
  • 2-pole
  • Snap-in version
  • Positively trip-free release
  • Method of operation acc. to IEC: S-type
  • Different rocker colours
  • Wide current range

Unique Selling Proposition

  • Unique UL rating of 277 VAC
  • Finely graded rated currents
  • High configurability (rocker colours, lettering, illumination)
  • IP65 with optional cover

Applications

  • Power tools
  • Medical and laboratory equipment
  • Industrial appliances
  • Equipment for construction
  • Cleaning equipment
  • Commercial and household kitchen appliances
  • Industrial Power
  • Industrial lighting arrays

UMT-H SMD Fuse

Description

  • 24 rated currents from 160 mA to 30 A
  • Square design: 5.3 x 16
  • Impermeable to potting compound used to achieve hermetic seal for use in intrinsically safe applications according to ATEx and IECEx requirements.

Unique Selling Proposition

  • High breaking capacity up to 1500 A
  • High rated voltages up to 277 VAC / 250 VDC
  • Compact design
  • Suitable for pulse-shaped continuous currents

Applications

  • Primary protection on SMD PCBs
  • Sensors
  • Power supplies
  • Intrinsically Safe
  • Illumination
  • Battery protection

FMAB HV

Description

  • Filter for 277 VAC or 400 VDC applications
  • 1 stage
  • Compact filter with high symmetrical attenuation

Unique Selling Proposition

  • For high AC- or DC-voltages
  • Excellent symmetrical attenuation
  • Completely enclosed steel housing
  • Optional overvoltage protection

Characteristics

  • For 277 VAC applications in North America WYE 480/277 volt system
  • For 400 VDC applications e.g. data center
  • Especially designed forapplications with symmetrical noise caused by switching semiconductors
  • Suitable for use in equipment according to IEC/UL 60950
  • Suitable for use in medical equipment according to IEC/UL 60601-1